Bringing Fresh Air Home
HueVen EFHRD-EP150IBC, EP200IBC, EP250IBC, HRD-EP100IBC, HRD-EP150IBCN
Certifications and Awards
Product Guide
Proper indoor ventilation is essential for clean air.
Blocks outside air and filters odors through its diffuser
CO₂ sensor with four tailored modes
Perfectly blocks fine dust and filters bacteria
Efficient energy technology that saves on heating and cooling bills
Don’t use just any filter! Certified HIMPEL ventilation system filters trap fine dust and viruses to keep your air clean.
1)[H13 HEPA Filter]
Test Date: April 2022
Testing Organization: KCL Korea Conformity Laboratories
Test Subject: HueVenEBSN HEPA Filter
Test Method: Based on KSB6141:2020 Type 1 test standards
Test Condition: Removal efficiency for particles of 0.3 µm diameter (KCI), test flow rate 150 m³/h, face velocity 0.71 m/s
Test Result: 99.99% removal of 0.3 µm fine dust particles
Test results may vary depending on particle size, test conditions, and usage environment.
[Antiviral Filter]
Test Date: February 2023
Testing Agency: KCL Korea Conformity Laboratories
Test Subject: HueVenEBSN Antiviral Filter
Test Method: Based on KSB6141:2020 Type 1 test standards
Test Conditions: Removal efficiency for 0.3 µm diameter particles (KCl), test flow rate 150 ㎡/h, face velocity 0.72 m/s
Test Result: 99.98% removal of 0.3 µm fine dust particles
Note: Results may vary depending on particle size, test conditions, and usage environment.
[UV Sterilization]
Test Date: November 2020
Testing Agency: KTL Korea Testing Laboratory
Test Subject: Himpel HueVen (Heat Recovery Ventilator) EBSN
Test Method: KOUVA AS 02:2019
Test Conditions: Removal efficiency of airborne bacteria (ATCC 12228), temperature 23°C, humidity 50%, test chamber 60 ㎡, test duration 60 minutes
Test Result: 99.8% reduction of airborne bacteria
Note: Results may vary depending on particle size, test conditions, and usage environment.
UV LED + TiO2-coated ceramic effectively sterilizes1 and removes various harmful bacteria while deodorizing for cleaner ventilation.
[Applying UV Photocatalytic Sterilization Technology]
Test Date: April 2022
Testing Organization: KTL Korea Testing Laboratory
Test Subject: HueVenEBSN UV Photocatalytic Sterilizer
Test Method: KOUVA AS 02:2019
Test Condition: Removal efficiency for 0.3 µm diameter particles (KCI), test flow rate 150㎡/h, face velocity 0.71m/s
Test Result: Airborne bacteria reduction rate 99.0%, airborne virus reduction rate 95.6%, ozone concentration up to 0.0023 ppm over 24 hours
This is 0.003 ppm lower than the permissible standard
Test results may vary depending on particle size, test conditions, and usage environment
With high-efficiency energy exchange technology, you can save up to 300,000 KRW in heating and cooling costs.
There may be differences in fees depending on whether a household is high-voltage or low-voltage.
Average monthly electricity usage for a family of four: 350 kWh, usage fee: 54,000 KRW
Source of average monthly fee: Korea Electric Power Corporation [Usage Fee Calculation]
Beyond the basic controller, we offer a range of smart options to manage your indoor air quality more conveniently.
Eco-friendly, recyclable EPP is harmless to humans, and offers excellent sound absorption, insulation, and durability. Enjoy ventilation without worrying about noise, and a rust-free device that is resistant to condensation and mold in winter.
Conveniently replace the filter through its detachable filter¹ case, and stay on top of maintenance with notifications from the room controller.
Filter & heat exchanger (cleaning)
-Based on 2,000 hours of operation (about 5 months when used 12 hours per day)
Filter (replacement)
-Based on 4,000 hours of operation (about 10 months when used 12 hours per day)
Heat exchanger (replacement)
-Based on 20,000 hours of operation (about 4 years and 1 month when used 12 hours per day)
*Product specifications and performance are subject to change without prior notice for quality improvement.